AAA Products International has a reputation for providing high-quality pneumatic control valves for over 50 years. From precision engineered rugged directional control air valves, high production rod threading machines to durable and efficient high-volume Tap & Drill production equipment, select AAA with confidence.

15722 products

AAA Differential Controlled Air Valve DO3DU

AAA Products International

AAA Differential Controlled Air Valve DO3DU

AAA Products International - Part Number: DO3DU

| Side Ported 3/8" NPTF | 2-position, single differential pilot, spring returned spool. Spool returns to position “C” when the button is pressed. | Spool Configuration: Regenerative center, ports 2 & 4 are connectect to port 1, ports 3 & 5 are blocked. | Valve Options: Factory installed muffler/flow controls in ports 3 and 5 (body styles 2, 3 & 4 only). | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve DO3D

AAA Products International

AAA Differential Controlled Air Valve DO3D

AAA Products International - Part Number: DO3D

| Side Ported 3/8" NPTF | 2-position, single differential pilot, spring returned spool. Spool returns to position “C” when the button is pressed. | Spool Configuration: Regenerative center, ports 2 & 4 are connectect to port 1, ports 3 & 5 are blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve DO3

AAA Products International

AAA Differential Controlled Air Valve DO3

AAA Products International - Part Number: DO3

| Side Ported 3/8" NPTF | 2-position, single differential pilot, spring returned spool. Spool returns to position “C” when the button is pressed. | Spool Configuration: Closed center, all ports are blocked in the center position. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve DO2U

AAA Products International

AAA Differential Controlled Air Valve DO2U

AAA Products International - Part Number: DO2U

| Side Ported 1/4" NPTF | 2-position, single differential pilot, spring returned spool. Spool returns to position “C” when the button is pressed. | Spool Configuration: Closed center, all ports are blocked in the center position. | Valve Options: Factory installed muffler/flow controls in ports 3 and 5 (body styles 2, 3 & 4 only). | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve DO2GU

AAA Products International

AAA Differential Controlled Air Valve DO2GU

AAA Products International - Part Number: DO2GU

| Side Ported 1/4" NPTF | 2-position, single differential pilot, spring returned spool. Spool returns to position “C” when the button is pressed. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: Factory installed muffler/flow controls in ports 3 and 5 (body styles 2, 3 & 4 only). | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve DO2G

AAA Products International

AAA Differential Controlled Air Valve DO2G

AAA Products International - Part Number: DO2G

| Side Ported 1/4" NPTF | 2-position, single differential pilot, spring returned spool. Spool returns to position “C” when the button is pressed. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve DO2D

AAA Products International

AAA Differential Controlled Air Valve DO2D

AAA Products International - Part Number: DO2D

| Side Ported 1/4" NPTF | 2-position, single differential pilot, spring returned spool. Spool returns to position “C” when the button is pressed. | Spool Configuration: Regenerative center, ports 2 & 4 are connectect to port 1, ports 3 & 5 are blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve DO2

AAA Products International

AAA Differential Controlled Air Valve DO2

AAA Products International - Part Number: DO2

| Side Ported 1/4" NPTF | 2-position, single differential pilot, spring returned spool. Spool returns to position “C” when the button is pressed. | Spool Configuration: Closed center, all ports are blocked in the center position. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve DO16PG

AAA Products International

AAA Differential Controlled Air Valve DO16PG

AAA Products International - Part Number: DO16PG

| Subplate Mounted 1 1/2" Flow | 2-position, single differential pilot, spring returned spool. Spool returns to position “C” when the button is pressed. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve DO16PD

AAA Products International

AAA Differential Controlled Air Valve DO16PD

AAA Products International - Part Number: DO16PD

| Subplate Mounted 1 1/2" Flow | 2-position, single differential pilot, spring returned spool. Spool returns to position “C” when the button is pressed. | Spool Configuration: Regenerative center, ports 2 & 4 are connectect to port 1, ports 3 & 5 are blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve DO16P

AAA Products International

AAA Differential Controlled Air Valve DO16P

AAA Products International - Part Number: DO16P

| Subplate Mounted 1 1/2" Flow | 2-position, single differential pilot, spring returned spool. Spool returns to position “C” when the button is pressed. | Spool Configuration: Closed center, all ports are blocked in the center position. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve DO12G

AAA Products International

AAA Differential Controlled Air Valve DO12G

AAA Products International - Part Number: DO12G

| Side Ported 1 1/2" NPTF | 2-position, single differential pilot, spring returned spool. Spool returns to position “C” when the button is pressed. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve DO12D

AAA Products International

AAA Differential Controlled Air Valve DO12D

AAA Products International - Part Number: DO12D

| Side Ported 1 1/2" NPTF | 2-position, single differential pilot, spring returned spool. Spool returns to position “C” when the button is pressed. | Spool Configuration: Regenerative center, ports 2 & 4 are connectect to port 1, ports 3 & 5 are blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve DO12

AAA Products International

AAA Differential Controlled Air Valve DO12

AAA Products International - Part Number: DO12

| Side Ported 1 1/2" NPTF | 2-position, single differential pilot, spring returned spool. Spool returns to position “C” when the button is pressed. | Spool Configuration: Closed center, all ports are blocked in the center position. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D8PG

AAA Products International

AAA Differential Controlled Air Valve D8PG

AAA Products International - Part Number: D8PG

| Subplate Mounted 1" Flow | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D8PD

AAA Products International

AAA Differential Controlled Air Valve D8PD

AAA Products International - Part Number: D8PD

| Subplate Mounted 1" Flow | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Regenerative center, ports 2 & 4 are connectect to port 1, ports 3 & 5 are blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D8P

AAA Products International

AAA Differential Controlled Air Valve D8P

AAA Products International - Part Number: D8P

| Subplate Mounted 1" Flow | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Closed center, all ports are blocked in the center position. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D8G

AAA Products International

AAA Differential Controlled Air Valve D8G

AAA Products International - Part Number: D8G

| Side Ported 1" NPTF | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D8D

AAA Products International

AAA Differential Controlled Air Valve D8D

AAA Products International - Part Number: D8D

| Side Ported 1" NPTF | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Regenerative center, ports 2 & 4 are connectect to port 1, ports 3 & 5 are blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D8

AAA Products International

AAA Differential Controlled Air Valve D8

AAA Products International - Part Number: D8

| Side Ported 1" NPTF | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Closed center, all ports are blocked in the center position. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D6PG

AAA Products International

AAA Differential Controlled Air Valve D6PG

AAA Products International - Part Number: D6PG

| Subplate Mounted 3/4" Flow | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D6PD

AAA Products International

AAA Differential Controlled Air Valve D6PD

AAA Products International - Part Number: D6PD

| Subplate Mounted 3/4" Flow | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Regenerative center, ports 2 & 4 are connectect to port 1, ports 3 & 5 are blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D6P

AAA Products International

AAA Differential Controlled Air Valve D6P

AAA Products International - Part Number: D6P

| Subplate Mounted 3/4" Flow | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Closed center, all ports are blocked in the center position. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D6G

AAA Products International

AAA Differential Controlled Air Valve D6G

AAA Products International - Part Number: D6G

| Side Ported 3/4" NPTF | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D6

AAA Products International

AAA Differential Controlled Air Valve D6

AAA Products International - Part Number: D6

| Side Ported 3/4" NPTF | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Closed center, all ports are blocked in the center position. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D6D

AAA Products International

AAA Differential Controlled Air Valve D6D

AAA Products International - Part Number: D6D

| Side Ported 3/4" NPTF | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Regenerative center, ports 2 & 4 are connectect to port 1, ports 3 & 5 are blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D4U

AAA Products International

AAA Differential Controlled Air Valve D4U

AAA Products International - Part Number: D4U

| Side Ported 1/2" NPTF | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Closed center, all ports are blocked in the center position. | Valve Options: Factory installed muffler/flow controls in ports 3 and 5 (body styles 2, 3 & 4 only). | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D4PG

AAA Products International

AAA Differential Controlled Air Valve D4PG

AAA Products International - Part Number: D4PG

| Subplate Mounted 1/2" Flow | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D4PD

AAA Products International

AAA Differential Controlled Air Valve D4PD

AAA Products International - Part Number: D4PD

| Subplate Mounted 1/2" Flow | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Regenerative center, ports 2 & 4 are connectect to port 1, ports 3 & 5 are blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D4P

AAA Products International

AAA Differential Controlled Air Valve D4P

AAA Products International - Part Number: D4P

| Subplate Mounted 1/2" Flow | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Closed center, all ports are blocked in the center position. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D4GU

AAA Products International

AAA Differential Controlled Air Valve D4GU

AAA Products International - Part Number: D4GU

| Side Ported 1/2" NPTF | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: Factory installed muffler/flow controls in ports 3 and 5 (body styles 2, 3 & 4 only). | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D4G

AAA Products International

AAA Differential Controlled Air Valve D4G

AAA Products International - Part Number: D4G

| Side Ported 1/2" NPTF | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D4DU

AAA Products International

AAA Differential Controlled Air Valve D4DU

AAA Products International - Part Number: D4DU

| Side Ported 1/2" NPTF | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Regenerative center, ports 2 & 4 are connectect to port 1, ports 3 & 5 are blocked. | Valve Options: Factory installed muffler/flow controls in ports 3 and 5 (body styles 2, 3 & 4 only). | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D4D

AAA Products International

AAA Differential Controlled Air Valve D4D

AAA Products International - Part Number: D4D

| Side Ported 1/2" NPTF | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Regenerative center, ports 2 & 4 are connectect to port 1, ports 3 & 5 are blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D4

AAA Products International

AAA Differential Controlled Air Valve D4

AAA Products International - Part Number: D4

| Side Ported 1/2" NPTF | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Closed center, all ports are blocked in the center position. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D3U

AAA Products International

AAA Differential Controlled Air Valve D3U

AAA Products International - Part Number: D3U

| Side Ported 3/8" NPTF | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Closed center, all ports are blocked in the center position. | Valve Options: Factory installed muffler/flow controls in ports 3 and 5 (body styles 2, 3 & 4 only). | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).