Skip to content

AAA Valves

While we showcase many parts on our website, thousands more are available through our trusted partners. If you're searching for a hard-to-find item, seek an  alternative part, or require assistance with product selection, don’t hesitate to contact us — we’re here to help and will do our best to assist you.

10718 products

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDOP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDOP

AAA Products International - Part Number: SS4PDOP

| Subplate Mounted 1/2" Flow | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4DMOP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4DMOP

AAA Products International - Part Number: SS4DMOP

| Side Ported 1/2" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS8DXZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS8DXZ

AAA Products International - Part Number: SS8DXZ

| Side Ported 1" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDON

AAA Products International - Part Number: SS4PDON

| Subplate Mounted 1/2" Flow | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS6EDL

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS6EDL

AAA Products International - Part Number: SS6EDL

| Side Ported 3/4" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4DML

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4DML

AAA Products International - Part Number: SS4DML

| Side Ported 1/2" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS8DZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS8DZ

AAA Products International - Part Number: SS8DZ

| Side Ported 1" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS6DXT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS6DXT

AAA Products International - Part Number: SS6DXT

| Side Ported 3/4" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDMZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDMZ

AAA Products International - Part Number: SS4PDMZ

| Subplate Mounted 1/2" Flow | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4DEDU

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4DEDU

AAA Products International - Part Number: SS4DEDU

| Side Ported 1/2" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Factory installed muffler/flow controls in ports 3 and 5 (body styles 2, 3 & 4 only). | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS8DXOP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS8DXOP

AAA Products International - Part Number: SS8DXOP

| Side Ported 1" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDO

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDO

AAA Products International - Part Number: SS4PDO

| Subplate Mounted 1/2" Flow | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4DL

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4DL

AAA Products International - Part Number: SS4DL

| Side Ported 1/2" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS6DXO

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS6DXO

AAA Products International - Part Number: SS6DXO

| Side Ported 3/4" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Valve Options: Locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS8DON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS8DON

AAA Products International - Part Number: SS8DON

| Side Ported 1" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS6DX

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS6DX

AAA Products International - Part Number: SS6DX

| Side Ported 3/4" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Valve Options: No options selected | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDMV

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDMV

AAA Products International - Part Number: SS4PDMV

| Subplate Mounted 1/2" Flow | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: High pressure solenoid, for “Internal Pilot” valves up to 300 psi. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4DEDZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4DEDZ

AAA Products International - Part Number: SS4DEDZ

| Side Ported 1/2" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS8DXT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS8DXT

AAA Products International - Part Number: SS8DXT

| Side Ported 1" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS6DXON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS6DXON

AAA Products International - Part Number: SS6DXON

| Side Ported 3/4" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDMON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDMON

AAA Products International - Part Number: SS4PDMON

| Subplate Mounted 1/2" Flow | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS8DX

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS8DX

AAA Products International - Part Number: SS8DX

| Side Ported 1" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Valve Options: No options selected | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4DM

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4DM

AAA Products International - Part Number: SS4DM

| Side Ported 1/2" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: No options selected | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDMO

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDMO

AAA Products International - Part Number: SS4PDMO

| Subplate Mounted 1/2" Flow | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4DEDOP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4DEDOP

AAA Products International - Part Number: SS4DEDOP

| Side Ported 1/2" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS6DXL

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS6DXL

AAA Products International - Part Number: SS6DXL

| Side Ported 3/4" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS8DT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS8DT

AAA Products International - Part Number: SS8DT

| Side Ported 1" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDMT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDMT

AAA Products International - Part Number: SS4PDMT

| Subplate Mounted 1/2" Flow | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS6DXOP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS6DXOP

AAA Products International - Part Number: SS6DXOP

| Side Ported 3/4" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4DEDT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4DEDT

AAA Products International - Part Number: SS4DEDT

| Side Ported 1/2" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS8DXL

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS8DXL

AAA Products International - Part Number: SS8DXL

| Side Ported 1" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDL

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDL

AAA Products International - Part Number: SS4PDL

| Subplate Mounted 1/2" Flow | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS6DV

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS6DV

AAA Products International - Part Number: SS6DV

| Side Ported 3/4" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: High pressure solenoid, for “Internal Pilot” valves up to 300 psi. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4DEDV

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4DEDV

AAA Products International - Part Number: SS4DEDV

| Side Ported 1/2" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: High pressure solenoid, for “Internal Pilot” valves up to 300 psi. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS8DXON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS8DXON

AAA Products International - Part Number: SS8DXON

| Side Ported 1" NPTF | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDMOP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SS4PDMOP

AAA Products International - Part Number: SS4PDMOP

| Subplate Mounted 1/2" Flow | Double solenoid, 2-position, friction position. Spool shifts and remains shifted when one solenoid or the other is momentarily or continuously energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).