Skip to content

AAA Valves

While we showcase many parts on our website, thousands more are available through our trusted partners. If you're searching for a hard-to-find item, seek an  alternative part, or require assistance with product selection, don’t hesitate to contact us — we’re here to help and will do our best to assist you.

10718 products

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY2DED

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY2DED

AAA Products International - Part Number: SY2DED

| Side Ported 1/4" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: No options selected | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12V

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12V

AAA Products International - Part Number: SY12V

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: High pressure solenoid, for “Internal Pilot” valves up to 300 psi. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12MO

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12MO

AAA Products International - Part Number: SY12MO

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GXT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GXT

AAA Products International - Part Number: SY12GXT

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12XV

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12XV

AAA Products International - Part Number: SY12XV

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Valve Options: High pressure solenoid, for “Internal Pilot” valves up to 300 psi. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12O

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12O

AAA Products International - Part Number: SY12O

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GV

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GV

AAA Products International - Part Number: SY12GV

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: High pressure solenoid, for “Internal Pilot” valves up to 300 psi. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY2X

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY2X

AAA Products International - Part Number: SY2X

| Side Ported 1/4" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Valve Options: No options selected | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY2DEDON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY2DEDON

AAA Products International - Part Number: SY2DEDON

| Side Ported 1/4" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GML

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GML

AAA Products International - Part Number: SY12GML

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GO

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GO

AAA Products International - Part Number: SY12GO

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GMT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GMT

AAA Products International - Part Number: SY12GMT

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GEDL

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GEDL

AAA Products International - Part Number: SY12GEDL

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12MV

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12MV

AAA Products International - Part Number: SY12MV

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: High pressure solenoid, for “Internal Pilot” valves up to 300 psi. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GM

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GM

AAA Products International - Part Number: SY12GM

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: No options selected | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY2XK

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY2XK

AAA Products International - Part Number: SY2XK

| Side Ported 1/4" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Valve Options: Threaded spool indicator pin (available only on models with body styles 2, 3 & 3P). | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY2XON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY2XON

AAA Products International - Part Number: SY2XON

| Side Ported 1/4" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12L

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12L

AAA Products International - Part Number: SY12L

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GL

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GL

AAA Products International - Part Number: SY12GL

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GEDOP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GEDOP

AAA Products International - Part Number: SY12GEDOP

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12MT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12MT

AAA Products International - Part Number: SY12MT

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12ML

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12ML

AAA Products International - Part Number: SY12ML

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GXON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GXON

AAA Products International - Part Number: SY12GXON

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GMZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GMZ

AAA Products International - Part Number: SY12GMZ

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GEDT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GEDT

AAA Products International - Part Number: SY12GEDT

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12EDZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12EDZ

AAA Products International - Part Number: SY12EDZ

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GMOP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GMOP

AAA Products International - Part Number: SY12GMOP

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GEDO

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GEDO

AAA Products International - Part Number: SY12GEDO

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GEDON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GEDON

AAA Products International - Part Number: SY12GEDON

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GMO

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GMO

AAA Products International - Part Number: SY12GMO

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GXZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GXZ

AAA Products International - Part Number: SY12GXZ

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12G

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12G

AAA Products International - Part Number: SY12G

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: No options selected | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12EDV

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12EDV

AAA Products International - Part Number: SY12EDV

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: High pressure solenoid, for “Internal Pilot” valves up to 300 psi. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12EDOP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12EDOP

AAA Products International - Part Number: SY12EDOP

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12EDT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12EDT

AAA Products International - Part Number: SY12EDT

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12DMOP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12DMOP

AAA Products International - Part Number: SY12DMOP

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).