Skip to content

Products


7602 products

OPAP 700

Pronal

OPAP 700

The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.

Part No. Dia. (mm) Width-Empty. (mm) Length-Empty (mm) Working Pressure (bar) Stem (")
OPAP 700 700 1050 1400 0.8 3/4"

The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.

Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.

OPAP 800

Pronal

OPAP 800

The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.

Part No. Dia. (mm) Width-Empty. (mm) Length-Empty (mm) Working Pressure (bar) Stem (")
OPAP 800 800 1200 1600 0.6 3/4"

The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.

Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.

OPL 100/150

Pronal

OPL 100/150

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 100/150 100 150 90 125 3 0.6 NA

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 100/200

Pronal

OPL 100/200

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 100/200 100 200 86 350 3 1.3 NA

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 100/250

Pronal

OPL 100/250

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 100/250 100 250 86 600 3 2.2 NA

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 125/200

Pronal

OPL 125/200

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 125/200 125 200 110 152 3 0.7 NA

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 150/250

Pronal

OPL 150/250

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 150/250 150 250 145 255 3 2 1xM8

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 150/300

Pronal

OPL 150/300

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 150/300 150 300 145 465 3 2.6 1xM8

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 200/400

Pronal

OPL 200/400

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 200/400 200 400 190 555 3 5.5 2xM10

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 200/500

Pronal

OPL 200/500

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 200/500 200 500 170 725 3 5.5 1xM8

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 30/60

Pronal

OPL 30/60

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 30/60 30 60 29 150 3 0.2 NA

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 300/600

Pronal

OPL 300/600

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 300/600 300 600 288 715 3 12 2xM10

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 400/800

Pronal

OPL 400/800

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 400/800 400 800 370 1030 3 22 2xM12

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 45/80

Pronal

OPL 45/80

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 45/80 45 80 43 150 3 0.3 NA

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 50/100

Pronal

OPL 50/100

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 50/100 50 100 45 110 3 0.3 NA

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 500/1000

Pronal

OPL 500/1000

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 500/1000 500 1000 472 1140 3 32.5 2xM12

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 500/1400

Pronal

OPL 500/1400

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 500/1400 500 1400 490 2200 1.5 55 2xM12

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 600/1200

Pronal

OPL 600/1200

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 600/1200 600 1200 570 1400 1.5 49 2xM16

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 600/1500

Pronal

OPL 600/1500

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 600/1500 600 1500 570 2180 1.5 65 3xM16

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 65/125

Pronal

OPL 65/125

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 65/125 65 125 63 250 3 0.4 NA

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 75/150

Pronal

OPL 75/150

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 75/150 75 150 70 350 3 0.8 NA

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 800/1600

Pronal

OPL 800/1600

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 800/1600 800 1600 770 2000 1.5 90 3xM16

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 800/2000

Pronal

OPL 800/2000

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 800/2000 800 2000 760 2750 1.5 125 4xM16

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPLS 100/200

Pronal

OPLS 100/200

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPLS 100/200 100 200 90 250 3 0.8 NA

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPLS 75/150

Pronal

OPLS 75/150

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPLS 75/150 75 150 70 195 3 0.5 NA

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPLT 100/200

Pronal

OPLT 100/200

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPLT 100/200 100 200 86 350 2.5 2 NA

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPLT 150/250

Pronal

OPLT 150/250

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPLT 150/250 150 250 145 255 2.5 3 M8

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPLT 150/300

Pronal

OPLT 150/300

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPLT 150/300 150 300 145 465 2.5 4 M8

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPLT1 200/400

Pronal

OPLT1 200/400

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPLT1 200/400 200 400 190 555 2.5 7 M10

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPLT1 200/500

Pronal

OPLT1 200/500

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPLT1 200/500 200 500 170 725 2.5 7 M10

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPLT1 300/600

Pronal

OPLT1 300/600

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPLT1 300/600 300 600 288 715 2.5 16 M10

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPLT1 400/800

Pronal

OPLT1 400/800

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPLT1 400/800 400 800 370 1030 2.5 29 M12

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPLT1 500/1000

Pronal

OPLT1 500/1000

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPLT1 500/1000 500 1 000 472 1140 2.5 41 M12

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPLT1 500/1400

Pronal

OPLT1 500/1400

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPLT1 500/1400 500 1 400 472 2200 1,5 66 M12

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPLT1 600/1200

Pronal

OPLT1 600/1200

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPLT1 600/1200 600 1 200 566 1400 1,5 59 M16

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPLT1 600/1500

Pronal

OPLT1 600/1500

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPLT1 600/1500 600 1 500 570 2180 1,5 76 M16

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.