AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PEDV

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PEDV

AAA Products International - Part Number: SY4PEDV

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: High pressure solenoid, for “Internal Pilot” valves up to 300 psi. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDOP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDOP

AAA Products International - Part Number: SY4PDOP

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDXT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDXT

AAA Products International - Part Number: SY4PDXT

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PEDO

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PEDO

AAA Products International - Part Number: SY4PEDO

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDT

AAA Products International - Part Number: SY4PDT

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDZ

AAA Products International - Part Number: SY4PDZ

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PGED

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PGED

AAA Products International - Part Number: SY4PGED

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: No options selected | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PEDL

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PEDL

AAA Products International - Part Number: SY4PEDL

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDXZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDXZ

AAA Products International - Part Number: SY4PDXZ

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDXOP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDXOP

AAA Products International - Part Number: SY4PDXOP

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDXO

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDXO

AAA Products International - Part Number: SY4PDXO

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Valve Options: Locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDMT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDMT

AAA Products International - Part Number: SY4PDMT

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDXL

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDXL

AAA Products International - Part Number: SY4PDXL

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDMZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDMZ

AAA Products International - Part Number: SY4PDMZ

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDV

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDV

AAA Products International - Part Number: SY4PDV

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: High pressure solenoid, for “Internal Pilot” valves up to 300 psi. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDON

AAA Products International - Part Number: SY4PDON

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PEDON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PEDON

AAA Products International - Part Number: SY4PEDON

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDO

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDO

AAA Products International - Part Number: SY4PDO

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDEDT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDEDT

AAA Products International - Part Number: SY4PDEDT

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDMOP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDMOP

AAA Products International - Part Number: SY4PDMOP

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDXV

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDXV

AAA Products International - Part Number: SY4PDXV

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Valve Options: High pressure solenoid, for “Internal Pilot” valves up to 300 psi. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDEDZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDEDZ

AAA Products International - Part Number: SY4PDEDZ

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDX

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDX

AAA Products International - Part Number: SY4PDX

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Valve Options: No options selected | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDEDV

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDEDV

AAA Products International - Part Number: SY4PDEDV

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: High pressure solenoid, for “Internal Pilot” valves up to 300 psi. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4P

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4P

AAA Products International - Part Number: SY4P

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: No options selected | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDL

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDL

AAA Products International - Part Number: SY4PDL

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDMV

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDMV

AAA Products International - Part Number: SY4PDMV

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: High pressure solenoid, for “Internal Pilot” valves up to 300 psi. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDMON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDMON

AAA Products International - Part Number: SY4PDMON

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDEDON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDEDON

AAA Products International - Part Number: SY4PDEDON

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDMO

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDMO

AAA Products International - Part Number: SY4PDMO

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDEDL

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDEDL

AAA Products International - Part Number: SY4PDEDL

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDML

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDML

AAA Products International - Part Number: SY4PDML

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDEDOP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDEDOP

AAA Products International - Part Number: SY4PDEDOP

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDM

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PDM

AAA Products International - Part Number: SY4PDM

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: No options selected | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PD

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PD

AAA Products International - Part Number: SY4PD

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: No options selected | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4OP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4OP

AAA Products International - Part Number: SY4OP

| Side Ported 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).