Skip to content

pronal


302 products

OFR 380

Pronal

OFR 380

Part No. Min Stopper (mm) Max Stopper (mm) Length of Ferrule (mm) Max. Inflation Pressure (bar) Max. Back Pressure (bar)
OFR 380 391 409 450 0.9 0.4

In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.

OFR 425

Pronal

OFR 425

Part No. Min Stopper (mm) Max Stopper (mm) Length of Ferrule (mm) Max. Inflation Pressure (bar) Max. Back Pressure (bar)
OFR 425 428 448 500 0.8 0.3

In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.

OFR 475

Pronal

OFR 475

Part No. Min Stopper (mm) Max Stopper (mm) Length of Ferrule (mm) Max. Inflation Pressure (bar) Max. Back Pressure (bar)
OFR 475 469 492 550 0.8 0.3

In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.

OFR 530

Pronal

OFR 530

Part No. Min Stopper (mm) Max Stopper (mm) Length of Ferrule (mm) Max. Inflation Pressure (bar) Max. Back Pressure (bar)
OFR 530 540 567 600 0.7 0.3

In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.

OFR 580

Pronal

OFR 580

Part No. Min Stopper (mm) Max Stopper (mm) Length of Ferrule (mm) Max. Inflation Pressure (bar) Max. Back Pressure (bar)
OFR 580 567 596 700 1.1 0.5

In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.

OFR 600

Pronal

OFR 600

Part No. Min Stopper (mm) Max Stopper (mm) Length of Ferrule (mm) Max. Inflation Pressure (bar) Max. Back Pressure (bar)
OFR 600 585 615 750 1.1 0.5

In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.

OFR 650

Pronal

OFR 650

Part No. Min Stopper (mm) Max Stopper (mm) Length of Ferrule (mm) Max. Inflation Pressure (bar) Max. Back Pressure (bar)
OFR 650 657 691 800 1 0.4

In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.

OFR 726

Pronal

OFR 726

Part No. Min Stopper (mm) Max Stopper (mm) Length of Ferrule (mm) Max. Inflation Pressure (bar) Max. Back Pressure (bar)
OFR 726 727 765 850 0.9 0.4

In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.

OFR 780

Pronal

OFR 780

Part No. Min Stopper (mm) Max Stopper (mm) Length of Ferrule (mm) Max. Inflation Pressure (bar) Max. Back Pressure (bar)
OFR 780 765 806 950 0.8 0.4

In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.

OFR 870

Pronal

OFR 870

Part No. Min Stopper (mm) Max Stopper (mm) Length of Ferrule (mm) Max. Inflation Pressure (bar) Max. Back Pressure (bar)
OFR 870 848 894 1100 0.7 0.4

In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.

OFR 900

Pronal

OFR 900

Part No. Min Stopper (mm) Max Stopper (mm) Length of Ferrule (mm) Max. Inflation Pressure (bar) Max. Back Pressure (bar)
OFR 900 885 933 1150 0.7 0.4

In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.

OFR 978

Pronal

OFR 978

Part No. Min Stopper (mm) Max Stopper (mm) Length of Ferrule (mm) Max. Inflation Pressure (bar) Max. Back Pressure (bar)
OFR 978 941 992 1200 0.6 0.3

In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.

Oil Storage Tank

Pronal

Oil Storage Tank

The oil storage tank is the ideal solution for temporary or permanent storage of dielectric oil. PRONAL flexible tanks are made from technical fabrics coated with elastomer, which are particularly suitable for oil storage. These fabrics are also resistant to extreme weather conditions.

This tank is mainly used for:

  • On-site maintenance operations
  • Commissioning operations on transformers
  • Rapid expansion of storage facilities
  • Storage awaiting recycling/treatment

This oil storage tank ranges from 1 to 300 m3. Its accessories are adapted to the most used oil regeneration units. The connection is easy and quick to set up.

Onion Water Tank - Opentank

Pronal

Onion Water Tank - Opentank

The OPENTANK onion water tank is in circular shape. It is composed of an inflatable or foam float.

In contrast to the closed flexible tank, this open storage solution allows for quick storage of raw or drinking water by its top opening. Thanks to its fast installation and pumping/filling and its light weight, it can be used in a punctual way. Moreover, it is foldable. Therefore, takes up very little space. It is also very easy to clean in case of water pollution by sludge, leaves, sand etc.

This open top water storage tank has been primarily designed for:

  • The storage of raw water dedicated to civil security. This solution is widely used by firemen to fight forest fires. Helicopters carry bambi buckets that will fill up quickly by dipping them into our open top water storage tanks.
  • And the storage of drinking water dedicated to humanitarian organizations.

However, this Onion Water Tank can also be used for the storage of industrial effluents or polluted water.

Like Pronal’s other flexible tanks, it is made of highly resistant PVC coated fabric (1300 gr/m2) and assembled by high frequency welding. This fabric is resistant to any temperature from -30°C to +70°C.

OPAP 1000

Pronal

OPAP 1000

The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.

Part No. Dia. (mm) Width-Empty. (mm) Length-Empty (mm) Working Pressure (bar) Stem (")
OPAP 1000 1000 1550 2050 0.4 3/4"

The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.

Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.

OPAP 150

Pronal

OPAP 150

The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.

Part No. Dia. (mm) Width-Empty. (mm) Length-Empty (mm) Working Pressure (bar) Stem (")
OPAP 150 150 230 550 1.2 1/4"

The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.

Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.

OPAP 200

Pronal

OPAP 200

The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.

Part No. Dia. (mm) Width-Empty. (mm) Length-Empty (mm) Working Pressure (bar) Stem (")
OPAP 200 200 300 550 1.2 1/4"

The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.

Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.

OPAP 250

Pronal

OPAP 250

The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.

Part No. Dia. (mm) Width-Empty. (mm) Length-Empty (mm) Working Pressure (bar) Stem (")
OPAP 250 250 380 600 1.2 1/4"

The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.

Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.

OPAP 300

Pronal

OPAP 300

The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.

Part No. Dia. (mm) Width-Empty. (mm) Length-Empty (mm) Working Pressure (bar) Stem (")
OPAP 300 300 450 700 1.2 1/4"

The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.

Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.

OPAP 400

Pronal

OPAP 400

The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.

Part No. Dia. (mm) Width-Empty. (mm) Length-Empty (mm) Working Pressure (bar) Stem (")
OPAP 400 400 600 800 1.2 1/4"

The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.

Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.

OPAP 500

Pronal

OPAP 500

The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.

Part No. Dia. (mm) Width-Empty. (mm) Length-Empty (mm) Working Pressure (bar) Stem (")
OPAP 500 500 750 1000 1.2 1/4"

The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.

Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.

OPAP 600

Pronal

OPAP 600

The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.

Part No. Dia. (mm) Width-Empty. (mm) Length-Empty (mm) Working Pressure (bar) Stem (")
OPAP 600 600 900 1200 1 1/4"

The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.

Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.

OPAP 700

Pronal

OPAP 700

The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.

Part No. Dia. (mm) Width-Empty. (mm) Length-Empty (mm) Working Pressure (bar) Stem (")
OPAP 700 700 1050 1400 0.8 3/4"

The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.

Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.

OPAP 800

Pronal

OPAP 800

The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.

Part No. Dia. (mm) Width-Empty. (mm) Length-Empty (mm) Working Pressure (bar) Stem (")
OPAP 800 800 1200 1600 0.6 3/4"

The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.

Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.

OPL 100/150

Pronal

OPL 100/150

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 100/150 100 150 90 125 3 0.6 NA

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 100/200

Pronal

OPL 100/200

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 100/200 100 200 86 350 3 1.3 NA

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 100/250

Pronal

OPL 100/250

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 100/250 100 250 86 600 3 2.2 NA

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 125/200

Pronal

OPL 125/200

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 125/200 125 200 110 152 3 0.7 NA

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 150/250

Pronal

OPL 150/250

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 150/250 150 250 145 255 3 2 1xM8

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 150/300

Pronal

OPL 150/300

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 150/300 150 300 145 465 3 2.6 1xM8

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 200/400

Pronal

OPL 200/400

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 200/400 200 400 190 555 3 5.5 2xM10

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 200/500

Pronal

OPL 200/500

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 200/500 200 500 170 725 3 5.5 1xM8

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 30/60

Pronal

OPL 30/60

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 30/60 30 60 29 150 3 0.2 NA

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 300/600

Pronal

OPL 300/600

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 300/600 300 600 288 715 3 12 2xM10

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 400/800

Pronal

OPL 400/800

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 400/800 400 800 370 1030 3 22 2xM12

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.

OPL 45/80

Pronal

OPL 45/80

OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.

Part No. Min Dia. (mm) Max Dia. (mm) Deflated Dia. (mm) Length (mm) Working Pressure Weight (Kg) Eye Bolt Size
OPL 45/80 45 80 43 150 3 0.3 NA

They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.