Passer au contenu

AAA Valves

While we showcase many parts on our website, thousands more are available through our trusted partners. If you're searching for a hard-to-find item, seek an  alternative part, or require assistance with product selection, don’t hesitate to contact us — we’re here to help and will do our best to assist you.

10718 produits

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY6XT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY6XT

AAA Products International - Part Number: SY6XT

| Side Ported 3/4" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDON

AAA Products International - Part Number: SY8PDON

| Subplate Mounted 1" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4GMT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4GMT

AAA Products International - Part Number: SY4GMT

| Side Ported 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4GMON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4GMON

AAA Products International - Part Number: SY4GMON

| Side Ported 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4XT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4XT

AAA Products International - Part Number: SY4XT

| Side Ported 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4GML

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4GML

AAA Products International - Part Number: SY4GML

| Side Ported 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY6X

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY6X

AAA Products International - Part Number: SY6X

| Side Ported 3/4" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Valve Options: No options selected | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4GMU

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4GMU

AAA Products International - Part Number: SY4GMU

| Side Ported 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Factory installed muffler/flow controls in ports 3 and 5 (body styles 2, 3 & 4 only). | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDMZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDMZ

AAA Products International - Part Number: SY8PDMZ

| Subplate Mounted 1" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY6XON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY6XON

AAA Products International - Part Number: SY6XON

| Side Ported 3/4" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDOP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDOP

AAA Products International - Part Number: SY8PDOP

| Subplate Mounted 1" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY6MZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY6MZ

AAA Products International - Part Number: SY6MZ

| Side Ported 3/4" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4GM

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4GM

AAA Products International - Part Number: SY4GM

| Side Ported 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: No options selected | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PXT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PXT

AAA Products International - Part Number: SY4PXT

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PZ

AAA Products International - Part Number: SY4PZ

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDMON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDMON

AAA Products International - Part Number: SY8PDMON

| Subplate Mounted 1" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4GEDZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4GEDZ

AAA Products International - Part Number: SY4GEDZ

| Side Ported 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY6OP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY6OP

AAA Products International - Part Number: SY6OP

| Side Ported 3/4" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDMOP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDMOP

AAA Products International - Part Number: SY8PDMOP

| Subplate Mounted 1" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDMT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDMT

AAA Products International - Part Number: SY8PDMT

| Subplate Mounted 1" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDMV

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDMV

AAA Products International - Part Number: SY8PDMV

| Subplate Mounted 1" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: High pressure solenoid, for “Internal Pilot” valves up to 300 psi. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PXL

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PXL

AAA Products International - Part Number: SY4PXL

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PT

AAA Products International - Part Number: SY4PT

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4T

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4T

AAA Products International - Part Number: SY4T

| Side Ported 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDEDZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDEDZ

AAA Products International - Part Number: SY8PDEDZ

| Subplate Mounted 1" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4U

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4U

AAA Products International - Part Number: SY4U

| Side Ported 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Factory installed muffler/flow controls in ports 3 and 5 (body styles 2, 3 & 4 only). | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PXOP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PXOP

AAA Products International - Part Number: SY4PXOP

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY6V

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY6V

AAA Products International - Part Number: SY6V

| Side Ported 3/4" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: High pressure solenoid, for “Internal Pilot” valves up to 300 psi. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4GL

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4GL

AAA Products International - Part Number: SY4GL

| Side Ported 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4GMO

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4GMO

AAA Products International - Part Number: SY4GMO

| Side Ported 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDEDT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDEDT

AAA Products International - Part Number: SY8PDEDT

| Subplate Mounted 1" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDMO

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY8PDMO

AAA Products International - Part Number: SY8PDMO

| Subplate Mounted 1" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4GEDL

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4GEDL

AAA Products International - Part Number: SY4GEDL

| Side Ported 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PXON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4PXON

AAA Products International - Part Number: SY4PXON

| Subplate Mounted 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4EDZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY4EDZ

AAA Products International - Part Number: SY4EDZ

| Side Ported 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY6T

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY6T

AAA Products International - Part Number: SY6T

| Side Ported 3/4" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).