Passer au contenu

D Differential Controlled Air Valves

AAA Products International - D - 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released.

43 produits

AAA Differential Controlled Air Valve D16PG

AAA Products International

AAA Differential Controlled Air Valve D16PG

AAA Products International - Part Number: D16PG

| Subplate Mounted 1 1/2" Flow | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D2

AAA Products International

AAA Differential Controlled Air Valve D2

AAA Products International - Part Number: D2

| Side Ported 1/4" NPTF | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Closed center, all ports are blocked in the center position. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D16PD

AAA Products International

AAA Differential Controlled Air Valve D16PD

AAA Products International - Part Number: D16PD

| Subplate Mounted 1 1/2" Flow | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Regenerative center, ports 2 & 4 are connectect to port 1, ports 3 & 5 are blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D16P

AAA Products International

AAA Differential Controlled Air Valve D16P

AAA Products International - Part Number: D16P

| Subplate Mounted 1 1/2" Flow | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Closed center, all ports are blocked in the center position. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D12

AAA Products International

AAA Differential Controlled Air Valve D12

AAA Products International - Part Number: D12

| Side Ported 1 1/2" NPTF | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Closed center, all ports are blocked in the center position. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D12G

AAA Products International

AAA Differential Controlled Air Valve D12G

AAA Products International - Part Number: D12G

| Side Ported 1 1/2" NPTF | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA Differential Controlled Air Valve D12D

AAA Products International

AAA Differential Controlled Air Valve D12D

AAA Products International - Part Number: D12D

| Side Ported 1 1/2" NPTF | 2-position, double differential pilot, friction positioned. Spool stays in shifted position when buttons are released. | Spool Configuration: Regenerative center, ports 2 & 4 are connectect to port 1, ports 3 & 5 are blocked. | Valve Options: No options selected. | Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. |

Additional options and combinations are available - Please inquire.


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).