Passer au contenu

SY Solenoid Valves

AAA Products International - SY - Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized.

1104 produits

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12XZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12XZ

AAA Products International - Part Number: SY12XZ

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY16PDEDO

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY16PDEDO

AAA Products International - Part Number: SY16PDEDO

| Subplate Mounted 1 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12XON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12XON

AAA Products International - Part Number: SY12XON

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY16PDEDON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY16PDEDON

AAA Products International - Part Number: SY16PDEDON

| Subplate Mounted 1 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Regenerative center, ports 2 & 4 are connected to port 1, ports 3 & 5 are blocked. | Solenoid Operator Form: DIN coil with ISO 4400 connection. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12Z

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12Z

AAA Products International - Part Number: SY12Z

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY16P

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY16P

AAA Products International - Part Number: SY16P

| Subplate Mounted 1 1/2" Flow | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: No options selected | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12ON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12ON

AAA Products International - Part Number: SY12ON

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12XT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12XT

AAA Products International - Part Number: SY12XT

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12MO

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12MO

AAA Products International - Part Number: SY12MO

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12XL

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12XL

AAA Products International - Part Number: SY12XL

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12OP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12OP

AAA Products International - Part Number: SY12OP

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GXON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GXON

AAA Products International - Part Number: SY12GXON

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12MZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12MZ

AAA Products International - Part Number: SY12MZ

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12MT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12MT

AAA Products International - Part Number: SY12MT

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12MOP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12MOP

AAA Products International - Part Number: SY12MOP

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12MON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12MON

AAA Products International - Part Number: SY12MON

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12O

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12O

AAA Products International - Part Number: SY12O

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12M

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12M

AAA Products International - Part Number: SY12M

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: No options selected | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12X

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12X

AAA Products International - Part Number: SY12X

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Valve Options: No options selected | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GXZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GXZ

AAA Products International - Part Number: SY12GXZ

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12V

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12V

AAA Products International - Part Number: SY12V

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: High pressure solenoid, for “Internal Pilot” valves up to 300 psi. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12ML

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12ML

AAA Products International - Part Number: SY12ML

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GXT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GXT

AAA Products International - Part Number: SY12GXT

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12T

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12T

AAA Products International - Part Number: SY12T

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12L

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12L

AAA Products International - Part Number: SY12L

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12MV

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12MV

AAA Products International - Part Number: SY12MV

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Closed cross over, all ports are blocked in the center position. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: High pressure solenoid, for “Internal Pilot” valves up to 300 psi. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GZ

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GZ

AAA Products International - Part Number: SY12GZ

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Factory assembled for “External Pilot” operation. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GM

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GM

AAA Products International - Part Number: SY12GM

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: No options selected | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GT

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GT

AAA Products International - Part Number: SY12GT

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: "Classic” coil with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Tapped solenoid exhaust, 1/8" NPTF. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GMV

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GMV

AAA Products International - Part Number: SY12GMV

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: High pressure solenoid, for “Internal Pilot” valves up to 300 psi. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GXOP

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GXOP

AAA Products International - Part Number: SY12GXOP

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: Non-locking, push pin style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GML

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GML

AAA Products International - Part Number: SY12GML

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Dust excluder cap. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GMON

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GMON

AAA Products International - Part Number: SY12GMON

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Solenoid Operator Form: Mold-Over coil, with 1/2"-14 NPT conduit connection, with 18" leads. | Valve Options: Non-locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GX

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GX

AAA Products International - Part Number: SY12GX

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: No options selected | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GXV

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GXV

AAA Products International - Part Number: SY12GXV

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: High pressure solenoid, for “Internal Pilot” valves up to 300 psi. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GXO

AAA Products International

AAA "Classic" Solenoid Controlled, Pilot Operated Air Valve SY12GXO

AAA Products International - Part Number: SY12GXO

| Side Ported 1 1/2" NPTF | Double solenoid, 3-position, spring centered. Spool returns to center, position “B”, when both coils are de-energized. | Spool Configuration: Float center, port 2 is connected to port 3, port 4 is connected to port 5, port 1 is blocked. | Valve Options: Locking, twist style, manual solenoid override. | Valve O-Ring Option: Viton for body styles 2, 3 & 3P, Buna-N for body styles 4, 6, 8, 12, 4P, 8P &16P. | Coil Voltage and Frequency: 120 Volts, 60 Hz |


If applicable, please confirm your required voltage:

24 volts, 60 Hz | 120 volts, 60 Hz | 240 volts, 60 Hz | 6 volts DC | 12 volts DC | 24 volts DC

Different O-ring materials (only applies to valve body O-rings) are possible for some models: -1 Neoprene for freon (-40°F to 225°F), -2 Silicon (-80°F to 400°F), -3 Viton for most aromatic gases (-20°F to 400°F, 600°F for short time). -4 Butyl Rubber (-60°F to 200°F). -5 Teflon (-250°F to 450°F). -7 Urethane, 70 Durometer (-65°F to 200°F). -9 Buna-N (-40°F to 250°F).