OFR 580
| Part No. | Min Stopper (mm) | Max Stopper (mm) | Length of Ferrule (mm) | Max. Inflation Pressure (bar) | Max. Back Pressure (bar) |
| OFR 580 | 567 | 596 | 700 | 1.1 | 0.5 |
In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.
Choose your option
OFR 600
| Part No. | Min Stopper (mm) | Max Stopper (mm) | Length of Ferrule (mm) | Max. Inflation Pressure (bar) | Max. Back Pressure (bar) |
| OFR 600 | 585 | 615 | 750 | 1.1 | 0.5 |
In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.
Choose your option
OFR 650
| Part No. | Min Stopper (mm) | Max Stopper (mm) | Length of Ferrule (mm) | Max. Inflation Pressure (bar) | Max. Back Pressure (bar) |
| OFR 650 | 657 | 691 | 800 | 1 | 0.4 |
In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.
Choose your option
OFR 726
| Part No. | Min Stopper (mm) | Max Stopper (mm) | Length of Ferrule (mm) | Max. Inflation Pressure (bar) | Max. Back Pressure (bar) |
| OFR 726 | 727 | 765 | 850 | 0.9 | 0.4 |
In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.
Choose your option
OFR 780
| Part No. | Min Stopper (mm) | Max Stopper (mm) | Length of Ferrule (mm) | Max. Inflation Pressure (bar) | Max. Back Pressure (bar) |
| OFR 780 | 765 | 806 | 950 | 0.8 | 0.4 |
In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.
Choose your option
OFR 870
| Part No. | Min Stopper (mm) | Max Stopper (mm) | Length of Ferrule (mm) | Max. Inflation Pressure (bar) | Max. Back Pressure (bar) |
| OFR 870 | 848 | 894 | 1100 | 0.7 | 0.4 |
In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.
Choose your option
OFR 900
| Part No. | Min Stopper (mm) | Max Stopper (mm) | Length of Ferrule (mm) | Max. Inflation Pressure (bar) | Max. Back Pressure (bar) |
| OFR 900 | 885 | 933 | 1150 | 0.7 | 0.4 |
In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.
Choose your option
OFR 978
| Part No. | Min Stopper (mm) | Max Stopper (mm) | Length of Ferrule (mm) | Max. Inflation Pressure (bar) | Max. Back Pressure (bar) |
| OFR 978 | 941 | 992 | 1200 | 0.6 | 0.3 |
In the event of a disaster, the emergency pipe plug inflates and acts as a valve that retains the polluting products. Once confined, these liquids are pumped or diverted to a retention basin. The sealing balloon thus stops the propagation of chemical products or fire water, eliminating any risk of pollution.
Choose your option
Oil Storage Tank
The oil storage tank is the ideal solution for temporary or permanent storage of dielectric oil. PRONAL flexible tanks are made from technical fabrics coated with elastomer, which are particularly suitable for oil storage. These fabrics are also resistant to extreme weather conditions.
This tank is mainly used for:
- On-site maintenance operations
- Commissioning operations on transformers
- Rapid expansion of storage facilities
- Storage awaiting recycling/treatment
This oil storage tank ranges from 1 to 300 m3. Its accessories are adapted to the most used oil regeneration units. The connection is easy and quick to set up.
Choose your option
Onion Water Tank - Opentank
The OPENTANK onion water tank is in circular shape. It is composed of an inflatable or foam float.
In contrast to the closed flexible tank, this open storage solution allows for quick storage of raw or drinking water by its top opening. Thanks to its fast installation and pumping/filling and its light weight, it can be used in a punctual way. Moreover, it is foldable. Therefore, takes up very little space. It is also very easy to clean in case of water pollution by sludge, leaves, sand etc.
This open top water storage tank has been primarily designed for:
- The storage of raw water dedicated to civil security. This solution is widely used by firemen to fight forest fires. Helicopters carry bambi buckets that will fill up quickly by dipping them into our open top water storage tanks.
- And the storage of drinking water dedicated to humanitarian organizations.
However, this Onion Water Tank can also be used for the storage of industrial effluents or polluted water.
Like Pronal’s other flexible tanks, it is made of highly resistant PVC coated fabric (1300 gr/m2) and assembled by high frequency welding. This fabric is resistant to any temperature from -30°C to +70°C.
Choose your option
OPAP 1000
The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.
| Part No. | Dia. (mm) | Width-Empty. (mm) | Length-Empty (mm) | Working Pressure (bar) | Stem (") |
| OPAP 1000 | 1000 | 1550 | 2050 | 0.4 | 3/4" |
The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.
Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.
Choose your option
OPAP 150
The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.
| Part No. | Dia. (mm) | Width-Empty. (mm) | Length-Empty (mm) | Working Pressure (bar) | Stem (") |
| OPAP 150 | 150 | 230 | 550 | 1.2 | 1/4" |
The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.
Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.
Choose your option
OPAP 200
The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.
| Part No. | Dia. (mm) | Width-Empty. (mm) | Length-Empty (mm) | Working Pressure (bar) | Stem (") |
| OPAP 200 | 200 | 300 | 550 | 1.2 | 1/4" |
The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.
Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.
Choose your option
OPAP 250
The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.
| Part No. | Dia. (mm) | Width-Empty. (mm) | Length-Empty (mm) | Working Pressure (bar) | Stem (") |
| OPAP 250 | 250 | 380 | 600 | 1.2 | 1/4" |
The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.
Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.
Choose your option
OPAP 300
The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.
| Part No. | Dia. (mm) | Width-Empty. (mm) | Length-Empty (mm) | Working Pressure (bar) | Stem (") |
| OPAP 300 | 300 | 450 | 700 | 1.2 | 1/4" |
The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.
Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.
Choose your option
OPAP 400
The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.
| Part No. | Dia. (mm) | Width-Empty. (mm) | Length-Empty (mm) | Working Pressure (bar) | Stem (") |
| OPAP 400 | 400 | 600 | 800 | 1.2 | 1/4" |
The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.
Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.
Choose your option
OPAP 500
The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.
| Part No. | Dia. (mm) | Width-Empty. (mm) | Length-Empty (mm) | Working Pressure (bar) | Stem (") |
| OPAP 500 | 500 | 750 | 1000 | 1.2 | 1/4" |
The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.
Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.
Choose your option
OPAP 600
The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.
| Part No. | Dia. (mm) | Width-Empty. (mm) | Length-Empty (mm) | Working Pressure (bar) | Stem (") |
| OPAP 600 | 600 | 900 | 1200 | 1 | 1/4" |
The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.
Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.
Choose your option
OPAP 700
The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.
| Part No. | Dia. (mm) | Width-Empty. (mm) | Length-Empty (mm) | Working Pressure (bar) | Stem (") |
| OPAP 700 | 700 | 1050 | 1400 | 0.8 | 3/4" |
The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.
Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.
Choose your option
OPAP 800
The Pollu-Plug Anti-Pollution Stopper was developed in the interest of protecting the environment. Once inflated, it helps prevent pollution by retaining and stopping toxic or liquid spills.
| Part No. | Dia. (mm) | Width-Empty. (mm) | Length-Empty (mm) | Working Pressure (bar) | Stem (") |
| OPAP 800 | 800 | 1200 | 1600 | 0.6 | 3/4" |
The emergency pipe plug is permanently installed in the pipes. It is maintained in the upper part of the pipe and does not interfere with the water flow.
Once installed, the plugging balloon is connected, by a flexible hose, to a control box near the manhole. It can be triggered manually in the box, or automatically using a remote electric control or a GSM remote control. Thanks to this control box we can inflate and deflate the pipe plug the shutter remotely. This system prevents the operator from going down in the pipe.
Choose your option
OPL 100/150
OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.
| Part No. | Min Dia. (mm) | Max Dia. (mm) | Deflated Dia. (mm) | Length (mm) | Working Pressure | Weight (Kg) | Eye Bolt Size |
| OPL 100/150 | 100 | 150 | 90 | 125 | 3 | 0.6 | NA |
They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.
Choose your option
OPL 100/200
OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.
| Part No. | Min Dia. (mm) | Max Dia. (mm) | Deflated Dia. (mm) | Length (mm) | Working Pressure | Weight (Kg) | Eye Bolt Size |
| OPL 100/200 | 100 | 200 | 86 | 350 | 3 | 1.3 | NA |
They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.
Choose your option
OPL 100/250
OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.
| Part No. | Min Dia. (mm) | Max Dia. (mm) | Deflated Dia. (mm) | Length (mm) | Working Pressure | Weight (Kg) | Eye Bolt Size |
| OPL 100/250 | 100 | 250 | 86 | 600 | 3 | 2.2 | NA |
They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.
Choose your option
OPL 125/200
OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.
| Part No. | Min Dia. (mm) | Max Dia. (mm) | Deflated Dia. (mm) | Length (mm) | Working Pressure | Weight (Kg) | Eye Bolt Size |
| OPL 125/200 | 125 | 200 | 110 | 152 | 3 | 0.7 | NA |
They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.
Choose your option
OPL 150/250
OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.
| Part No. | Min Dia. (mm) | Max Dia. (mm) | Deflated Dia. (mm) | Length (mm) | Working Pressure | Weight (Kg) | Eye Bolt Size |
| OPL 150/250 | 150 | 250 | 145 | 255 | 3 | 2 | 1xM8 |
They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.
Choose your option
OPL 150/300
OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.
| Part No. | Min Dia. (mm) | Max Dia. (mm) | Deflated Dia. (mm) | Length (mm) | Working Pressure | Weight (Kg) | Eye Bolt Size |
| OPL 150/300 | 150 | 300 | 145 | 465 | 3 | 2.6 | 1xM8 |
They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.
Choose your option
OPL 200/400
OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.
| Part No. | Min Dia. (mm) | Max Dia. (mm) | Deflated Dia. (mm) | Length (mm) | Working Pressure | Weight (Kg) | Eye Bolt Size |
| OPL 200/400 | 200 | 400 | 190 | 555 | 3 | 5.5 | 2xM10 |
They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.
Choose your option
OPL 200/500
OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.
| Part No. | Min Dia. (mm) | Max Dia. (mm) | Deflated Dia. (mm) | Length (mm) | Working Pressure | Weight (Kg) | Eye Bolt Size |
| OPL 200/500 | 200 | 500 | 170 | 725 | 3 | 5.5 | 1xM8 |
They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.
Choose your option
OPL 30/60
OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.
| Part No. | Min Dia. (mm) | Max Dia. (mm) | Deflated Dia. (mm) | Length (mm) | Working Pressure | Weight (Kg) | Eye Bolt Size |
| OPL 30/60 | 30 | 60 | 29 | 150 | 3 | 0.2 | NA |
They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.
Choose your option
OPL 300/600
OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.
| Part No. | Min Dia. (mm) | Max Dia. (mm) | Deflated Dia. (mm) | Length (mm) | Working Pressure | Weight (Kg) | Eye Bolt Size |
| OPL 300/600 | 300 | 600 | 288 | 715 | 3 | 12 | 2xM10 |
They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.
Choose your option
OPL 400/800
OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.
| Part No. | Min Dia. (mm) | Max Dia. (mm) | Deflated Dia. (mm) | Length (mm) | Working Pressure | Weight (Kg) | Eye Bolt Size |
| OPL 400/800 | 400 | 800 | 370 | 1030 | 3 | 22 | 2xM12 |
They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.
Choose your option
OPL 45/80
OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.
| Part No. | Min Dia. (mm) | Max Dia. (mm) | Deflated Dia. (mm) | Length (mm) | Working Pressure | Weight (Kg) | Eye Bolt Size |
| OPL 45/80 | 45 | 80 | 43 | 150 | 3 | 0.3 | NA |
They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.
Choose your option
OPL 50/100
OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.
| Part No. | Min Dia. (mm) | Max Dia. (mm) | Deflated Dia. (mm) | Length (mm) | Working Pressure | Weight (Kg) | Eye Bolt Size |
| OPL 50/100 | 50 | 100 | 45 | 110 | 3 | 0.3 | NA |
They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.
Choose your option
OPL 500/1000
OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.
| Part No. | Min Dia. (mm) | Max Dia. (mm) | Deflated Dia. (mm) | Length (mm) | Working Pressure | Weight (Kg) | Eye Bolt Size |
| OPL 500/1000 | 500 | 1000 | 472 | 1140 | 3 | 32.5 | 2xM12 |
They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.
Choose your option
OPL 500/1400
OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.
| Part No. | Min Dia. (mm) | Max Dia. (mm) | Deflated Dia. (mm) | Length (mm) | Working Pressure | Weight (Kg) | Eye Bolt Size |
| OPL 500/1400 | 500 | 1400 | 490 | 2200 | 1.5 | 55 | 2xM12 |
They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.
Choose your option
OPL 600/1200
OPL/OPLT inflatable plugs are used to temporarily and effectively plug your pipe networks and systems.
| Part No. | Min Dia. (mm) | Max Dia. (mm) | Deflated Dia. (mm) | Length (mm) | Working Pressure | Weight (Kg) | Eye Bolt Size |
| OPL 600/1200 | 600 | 1200 | 570 | 1400 | 1.5 | 49 | 2xM16 |
They come in a variety of diameters and can be used in a wide range of applications, including sewage, rainwater and wastewater networks with the NR range, and hydrocarbons and chemicals with the NBR* range.